Negative Pressure Wound Therapy Systems

Source NPWT systems and compatible consumables through one coordinated product range. Explore NP-100, NP-600, and  NP-800 systems, disposable NPWT canisters, and NPWT dressing kits. Request model-specific product information and documentation for your target market.

  • Wound NPWT system
  • Wound Vac canister
  • NPWT dressing kits
Get Our Best Quotation
final contact form

A Coordinated NPWT Product Range for Professional Procurement

PROMED supports medical-device distributors, healthcare providers, and procurement teams sourcing negative pressure wound therapy systems and related consumables. Product selection should be based on the required device configuration, compatible consumables, destination market, and documentation requirements.

Choose Your NPWT System

Portable Negative Pressure Wound Therapy Products NP-200

A compact NPWT system for buyers evaluating a portable system configuration.

Negative Pressure Wound Therapy Pump NP-600

A professional NPWT system. Confirm the model configuration, compatible consumables, and available documentation before ordering.

Negative Pressure Wound Therapy Machine NP-800

A professional NPWT system with an instillation configuration option.

Complete the System with Configured Consumables

Select a disposable canister by device model, capacity, connector configuration, and packaging requirements. Do not assume that a canister is interchangeable across NPWT systems.

NPWT dressing kit components for replenishment reference

Select an NPWT dressing kit by device platform, tubing configuration, foam format and required dimensions. Confirm the applicable kit before placing an order.

Black foam dressing pieces and associated tubing

Select a foam dressing kit by material, foam format, and required dimensions. Confirm the applicable kit before placing an order.

Complementary Wound Cleaning and Debridement Equipment

CareMaster is a separate wound-cleaning and debridement equipment range for professional procurement. It should be selected independently, with its own configuration, consumables, and documentation requirements.

CareMaster E including ultrasonic debridement, high-pressure irrigation, and negative pressure suction.

Product Functions: Ultrasound Debridement + High-Pressure Flushing

Wound Debridement with 25 kHz Ultrasound

Why PROMED?

One-stop solution

You can buy NPWT machines, VAC canisters, and foam dressing kits from us.

Hospital room environment illustrating a procurement setting
Advanced Technology

Located in China’s innovation capital, it is easier to access the most cutting-edge technology and always keep up with the international advanced level.

Black foam dressing kit with tubing and film components
Limited MOQ

Lower MOQ requirements, lessing risk, and provide a better option for your startup business.

Warranty/After-sales

We provide 1-2 years warranty service to our customers. Please feel free to contact us for more information about products.

Model-Specific Documentation and Registration Support

PROMED is an authorized medical-device distributor and supplier. Product information and supporting documentation are provided through authorized supply partners. Model-specific certification and registration-support materials can be assessed according to product configuration and destination-market requirements. Document availability and local regulatory acceptance must be confirmed before purchase or submission.

Instillation Function of NPWT

Warnings!

Indications of NPWT
NPWT indications
  • Pressure Ulcers
  • Diabetic/Neuropathic Ulcers
  • Venous Insufficiency Ulcers
  • Traumatic Wounds
  • Post-operative Wounds
  • Skin Flaps/Grafts
  • Explored Fistulas
  •  …
Banner of the Page of NPWT
Give you factory prices and VIP services

PROMED support OEM/ODM and advocate for long-term, stable cooperative relationships. When you buy goods from us, I will ensure that you are satisfied when you receive them.

Model NP-800 NP-600 NP-200/NP-100
Power Supply AC 100V-240V, 50/60Hz
Input power ≤120VA, Input voltage AC 15V
AC 100V-240V, 50/60Hz
Input power ≤120VA, Input voltage AC 15V
AC 100V-240V, 50/60Hz, ≤60VA
Battery Rechargeable lithium-ion battery: 5200mAh, 11.2V Rechargeable lithium-ion battery: 5200mAh, 11.2V Rechargeable lithium-ion battery: 5200mAh, 7.4V
Therapy Modes Cleaning Drainage Mode(Mode D, E, F) & Negative Pressure Drainage Mode (Continuous, Intermittent, or Dynamic) Negative Pressure Drainage Mode (Continuous, Intermittent, or Dynamic) Continuous, Intermittent
Screen 7” color touch screen, 65K, LED-backlit, resolution 1024 x 600 7” color touch screen, 65K, LED-backlit, resolution 1024 x 600 2″ Color LCD Screen, LED-backlit
Lock Screen Yes Yes Yes
Auto Lock Screen Yes, display lock out after 10mintues Yes, display lock out after 10mintues No
Canister 500ml/1000ml 500ml/1000ml 300ml
Negative Pressure Range 0~-500mmHg
For Cleaning mode, Continuous, and Intermittent modes: 0~-500mmHg
For the Dynamic mode: -25~-200mmHg
Accuracy of negative pressure: The error is ±5mmHg for 0~-100mmHg (including -100mmHg), and ±5% for -100~-500mmHg.
Regulation step: 25mmHg.
For Continuous, and Intermittent modes: 0~-500mmHg
For the Dynamic mode: -25~-200mmHg
Accuracy of negative pressure: The error is ±5mmHg for 0~-100mmHg (including -100mmHg), and ±5% for -100~-500mmHg.
Regulation step: 25mmHg.
-50~-200mmHg;
Accuracy of negative pressure: The error is ±10mmHg for -50~-100mmHg (including -100mmHg), and ±10% for -100~-200mmHg.
Regulation step: 10mmHg.
Pumping Speed >8L/min (when working at full power) >8L/min (when working at full power) >1L/min (when working at full power)
Drainage Intensity The drainage intensity can be set to Low, Medium and High levels. The drainage intensity can be set to Low, Medium and High levels. Can not be adjusted
Noise <55dB(A) <55dB(A) <55dB(A)
Battery Performance At least 6h;
To fully charge the battery, 6h is required;
Charging/discharging cycles: ≥300
At least 6h;
To fully charge the battery, 6h is required;
Charging/discharging cycles: ≥300
At least 12h;
To fully charge the battery, 6h is required;
Charging/discharging cycles: ≥300
Cycle lifes of the main unit 3000h 3000h 3000h
GPRS NO NO YES
Bluetooth Yes, for mobile app monitor and control Yes, for mobile app monitor and control NP-200: YES;
Size 200 × 220 × 275mm (L×W×H); 200 × 220 × 275mm (L×W×H); 60 × 130 × 160mm (L×W×H);
Weight N.W: 3.7kg;
G.W: 6.1kg.
N.W: 3.7kg;
G.W: 6.1kg.
N.W: 0.6kg;
G.W: 1.0kg.
Protection functions Overflow protection; Lock screen (auto); High pressure alarm; Low pressure alarm; Canister full alarm; Low battery alarm; Tubing blockage alarm Overflow protection; Lock screen (auto); High pressure alarm; Low pressure alarm; Canister full alarm; Low battery alarm; Tubing blockage alarm Overflow protection; Lock screen (manual); High pressure alarm; Low pressure alarm; Canister full alarm; Low battery alarm
Operation Environment Normal operating temperature: 5°C~40°C;
Normal operating humidity: 10%~80%;
Atmospheric pressure: 700hPa~1060hPa;
Power supply: voltage: AC 100V~240V; frequency: 50/60Hz;
The environment should, whenever possible, be free from dust, mechanical vibration, sources of big noise, high-temperature area and power interference;
Normal operating temperature: 5°C~40°C;
Normal operating humidity: 10%~80%;
Atmospheric pressure: 700hPa~1060hPa;
Power supply: voltage: AC 100V~240V; frequency: 50/60Hz;
The environment should, whenever possible, be free from dust, mechanical vibration, sources of big noise, high-temperature area and power interference;
Normal operating temperature: 5°C~40°C;
Normal operating humidity: 10%~80%;
Atmospheric pressure: 700hPa~1060hPa;
Power supply: voltage: AC 100V~240V; frequency: 50/60Hz;
The environment should, whenever possible, be free from dust, mechanical vibration, sources of big noise, high-temperature area and power interference;
Parameter CareMaster-E CareMaster-G CareMaster-H
Standard configuration Ultrasonic debridement, high-pressure flushing and negative-pressure suction Ultrasonic debridement and high-pressure flushing Ultrasonic debridement
Ultrasonic debridement Standard Standard Standard
High-pressure flushing Standard Standard Optional
Negative-pressure suction Standard Optional Optional
Negative-pressure trolley Standard Optional Optional
Foot switch Double foot switches Double foot switches Single foot switch
Recommended selection Full-function wound-cleaning configuration Debridement and flushing configuration Ultrasonic debridement-focused configuration

Technical Parameters

Parameter CareMaster-E CareMaster-G CareMaster-H
Rated voltage a.c. 100-240 V a.c. 100-240 V a.c. 100-240 V
Rated frequency 50/60 Hz 50/60 Hz 50/60 Hz
Input power 300 VA 300 VA 300 VA
Display 10-inch colour touchscreen, 1024 × 600 10-inch colour touchscreen, 1024 × 600 10-inch colour touchscreen, 1024 × 600
Main unit output frequency 15-45 kHz 15-45 kHz 15-45 kHz
Working frequency 25 kHz ± 1 kHz 25 kHz ± 1 kHz 25 kHz ± 1 kHz
Effective ultrasonic output power < 50 W < 50 W < 50 W
Maximum debridement liquid flow ≥ 100 mL/min ≥ 100 mL/min ≥ 100 mL/min
Debridement probe amplitude ≥ 70 μm ≥ 70 μm ≥ 70 μm
Maximum debridement liquid temperature ≤ 35 °C ≤ 35 °C ≤ 35 °C
High-pressure flushing flow ≥ 400 mL/min ≥ 400 mL/min Confirm if flushing option is included
Maximum flushing pressure 0.6 ± 0.05 MPa 0.6 ± 0.05 MPa Confirm if flushing option is included
Extreme negative pressure ≥ 0.08 MPa Confirm if suction option is included Confirm if suction option is included
Air pumping rate ≥ 20 L/min Confirm if suction option is included Confirm if suction option is included
Storage canister capacity ≥ 2 L Confirm if suction option is included Confirm if suction option is included
Noise ≤ 70 dB(A) ≤ 70 dB(A) ≤ 70 dB(A)
Electrical safety classification Class I, Type B applied part Class I, Type B applied part Class I, Type B applied part
Foot switch protection IP68 IP68 IP68
Maximum continuous loading time 99 min 99 min 99 min
Net weight 8.6 kg 8.6 kg 7.3 kg
Gross weight 15 kg 14.5 kg 12.5 kg
Main unit package size 470 × 455 × 390 mm Confirm for supplied configuration Confirm for supplied configuration

Configuration Note: Optional functions, accessories, trolley configuration and packaging must be confirmed against the final quotation and supplied model configuration. The device is intended for trained healthcare professionals and must be used according to the current Instructions for Use.

Quick Guide to Operation

Please let a trained doctor or nurse operate the device.

  1. Pre-treat the wounds by doctors/nurses;
  2. Debride and clean the wounds.
  3. Evaluate the size of wounds.
  4. Cut the foam to size and put it on the wound,
  5. Cut the film (if necessary) and cover the wound and the foam
  6. Cut a small hole in the film, and connect it with the tubing
  7. Connect the tubing to the NPWT device, and make sure the connection is ok.
  8. Set the treatment parameters, then click Start.
  9. Finally, monitor the status of the wound and device.

The above is a brief operating instruction. Please follow the instruction manual for specific steps.

Can I source the NPWT system and consumables together?

Yes. Please provide the required device model, canister capacity, dressing-kit requirement, quantity and destination market. Compatibility is confirmed against the requested configuration.

How do I select a compatible canister or dressing kit?

Compatibility depends on the NPWT device model, interface and configured consumable range. Share your device requirement before ordering; do not select only by appearance or capacity.

Does NP-800 offer an instillation configuration?

NP-800 can be discussed as an NPWT configuration with an instillation option. Please request current model-specific information and documentation before purchase.

Can PROMED support local registration preparation?

We can assess and provide available product documentation for your target market, subject to the specific model, destination-market requirements and document availability. Regulatory approval is determined by the competent local authority.

Send Your Inquiry Today
final contact form
Update cookies preferences