• 8inch HD Display Electronic Blood Pressure Monitor
  • 8inch HD Display Electronic Blood Pressure Monitor

Electronic Blood Pressure Monitor LLK-S602

LLK-S602 Electronic Blood Pressure Monitor is a digital monitor intended for Adult (including pregnant)use in measuring blood pressure (SYS and DIC) and pulse rate, and the physician references the result to diagnose at the Hospital and other medical establishments.

General Introduction

The product meets Medical high standards, intelligent and more precise Identity recognition, and Results can be printed. The Voltage reduction oscilloscope method and the auscultatory method are dual methods for more accurate measurement.

Large & Clear 8 inch HD Display

LARGE SCREEN DISPLAYS CLEAR READING
Make the data clear at a glance
8-inch LCD high-definition display, easy-to-read blood pressure, and the elderly can see the children more at ease.

 

Key functions

Emergency stop button: During the measurement, short-press the “emergency stop” button to stop the measurement in an emergency. All the states will return to their original positions. Press the “emergency stop” button to return to the blood pressure measurement mode.

Start/stop button: put the arm into the arm tube, press the elbow at the position of the elbow contact switch, and short-press the “start/stop” button. Start to measure blood pressure, short-press again during the measurement, stop the measurement, and return to the original position.

Set button: Long-press the “Set” button to enter the setting mode. After the setting is completed, press the “Setting” key to exit the settings mode.

OK button: In the setting mode, short-press the “OK” button to confirm the current option; In the memory mode, short-press the “OK” button to exit the memory mode.

Correct Measurement Procedure

 Correct measurement posture and precautions

Please be sure to follow the correct measurement method below to get the correct blood pressure value.

  1. Straighten your body and maintain a correct sitting posture.
  2. After taking 5-6 deep breaths before measurement, resume natural breathing, relax shoulders and arms to relax the whole body.
  3. When measuring, keep the middle of the arm tube at the same height as the heart.
  4. During the measurement process, do not force your hands, do not talk, and keep sitting still until the measurement is completed.
  5.  In case of an emergency during the measurement, you can press the “emergency stop” button to terminate the measurement.

Electronic Blood Pressure Monitor LLK-S602

Specifications:

Measuring Method step-down oscillometric method + Korotkoff sound method
Display  8-inch HD display Screen
Measurement Range Blood Pressure: 0~299mmHg;
Resolution Ratio 1mmHg
Accuracy Blood pressure: ±3mmHg;
Pulse rate: ±3bpm or ±3%
Measurement Time Approx. 20s
Voice Broadcast Voice introduction of operation & reading;
Power Input AV 100-240V, 50/60Hz
Printer Thermal Printing;
Paper Size: 58x50mm; Auto cutting;
Memories 99 readings
Memory & Connection Port  USB/RS232/Bluetooth settings
Cuff Cylinder 4 directions adjustable. Up-Down, Left-Right
Cuff Circumstance 24-46cm
Size/weight (mm/Kg) 440mm x 497mm x 277mm /4.5Kg

 

 

How to use the arm tube?
  1. The arm tube adopts ergonomic design,which can move up and down by 10 degrees, adaptingto arms of different lengths, as shown in Figure l,allowing the user to The user measures bloodpressure in a comfortable position. move up anddown 10 degree.
  2. Put the right hand into the arm barrel, and the elbow should be placed at theposition of the elbow contact switch, as shown in Figure 2
  3. When the elbow is not placed at the position of the elbow contact switch, “pleaseplace the elbow on the elbow contact switch, arm Relax” prompt icon will flash (Figure 3),when the elbow is correctly placed on the position of the elbow contact switch, theprompt “Pay attention to the position of the elbow” will disappear (Figure 4), sit in thecorrect measurement posture, and prepare to start measuring blood pressure.Please place your elbow on the elbow contact switch, arm relaxed/measured, do notmove your arm
How to stored measurement data?

The blood pressure monitor stores the latest 99 sets of memory values. After eachmeasurement, the blood pressure monitor will automaticallythe measurement data.

Short press the “Previous Page” key to view the previous set of measurement data, andshort press the “Next Page” key to view the next set of measurement data.Measured value on the first page/measured value on the second page/measured valueon the third page/measured value on the fourth page When the volume is fully loaded, the old measurement data will be overwritten by thenew data.

View memory
Short press the “memory” button to enter the memory mode, display the historicaldata of blood pressure measurement, display the first set of historical data, and countlessdisplay blank.

Send Your Inquiry Today
final contact form
Update cookies preferences
Scroll to Top